DescriptionRainwater filter for larger roof areas. The Twin Filter can be installed in a separate manhole or vault or in a frost-protected area inside on the tank wall. Typically, standard pre-cast concrete vaults are used (1000 mm or 40-inch diameter). The filter can be delivered to the site pre-installed in the vault. Two step cleaning system, with high level of filtering efficiency, independent of flow rate. Due to the steep inclination of the filter cartridge the debris and dirt are continuously carried away through the outlet pipe - waste stream. The cleaned water is conveyed into the storage tank. Connection capacity for roof areas up to 7,500 ft². A bypass-installation is also available for larger roof areas. Connections: 2 tank inlets (4-inch & 6-inch), 2 outlets to tank (4-inch & 6-inch), 2 outlets to waste stream (4-inch & 6-inch) Depending on the amount of debris loading, the filter only has to be inspected 1 – 2 times during the year. During inspection cleaning may be necessary. |
|
|
How it works
Advice: Due to the horizontal position of the filter cartridge, the filter gets dirtier more rapidly as a filter cartridge with steep inclination. We therefore recommend using the Backwashing Device and periodic cleaning with detergent and brush in order to degrease the filter sieve. Pollen contains grease thus the water rolls off on the surface. |
|
|
Technical DataRainwater inlet: 2 x 4-inch Height difference between inlet and Housing and cascade material: Polyethylene Filter cartridge: Stainless steel 1.4301 Mesh size: 0.65 mm (0.03 Inches) Weight: 16 kg (35.2 Pounds) |
|
|
||
|
|
ExampleTwin Filter installed in a concrete shaft. |
|
|
|
|
|
DescriptionSelf cleaning rainwater filter for installation in the rainwater storage tank or in the ground before the tank or in the ground before the tank. Two step cleaning system, allows high level of filtering efficiency, independent of flow rate. The steep inclination of the filter cartridge allows debris and dirt to be continuously rinsed through the outlet pipe – waste stream. The filtered water is conveyed into the storage tank. Low maintenance requirement; the filter insert is easily removed for inspection and cleaning and does not have to be changed. Optional debris retention basket can be supplied. Relative connection capacity for roof areas up to 3,500 ft². Height difference between inlet and outlet just 300 mm (11.8 Inches). Depending on the amount of debris loading, the filter only has to be inspected 1 - 2 times during the year. During inspection cleaning may be necessary. |
|
|
How it works
|
|
|
Technical DataFilter according to DIN 1989-2, Type C Connection inlet: 2 x 4-inch Height difference between rainwater inlet and outlet 300 mm (11.8 Inches). Housing material: Polyethylene Filter cartridge: Stainless steel 1.4301 Material Cascade insert: Polyethylene Weight: 6.2 kg (13.6 lbs) |
|
|
||
|
|
Example 1Installation with telescopic extension in the ground before a plastic tank. |
|
|
||
|
|
Example 2Installation before a concrete tank. |
|
|
||
|
|
Accessories 13P Telescopic Extension Art.-Nr. 1000560 |
|
|
||
|
|
Accessories 2Removal Handle Art.-Nr. 1000550 |
|
|
|