INDUSTRIAL FILTERS


Volume Filter VF-2

Description

Highly efficient two step cascade filtration, independent of flow rate. For larger roof areas where underground installation is desired utilizing a pre-cast concrete manhole or vault. Typically, 1000 mm (40-inch) diameter pre-cast concrete vaults are used.

Due to the steep inclination of the filter cartridge the debris are continuously carried away with each rain event. The outlet pipe is connected at the base of the pre-cast vault wall. The debris fall down to the bottom of the vault and are carried out downstream. The filtered water is conveyed into the storage tank.

Relative connection capacity for roof areas up to 9,000 ft². A bypass-installation is also available for larger roof areas.

Max. Flow Rate Sieve insert 3.0 /sec = 10.8 m³ (14.12 ft³) filtered water per hour.

Rainwater Inlet: 200 mm (8-inches)
Outlet into tank: 150 mm (6-inches)
Outlet into waste stream: 200 mm (8-inches)
Height difference between inlet and outlet 320 mm (12.6-inches).

Depending on the amount of debris loading, the filter only has to be inspected 1 – 2 times during the year. During inspection cleaning may be necessary.

How it works

  1. As water arrives the level builds up and overtops the filter lip, so ensuring it is distributed evenly across the whole width of the filter cascade.
  2. Pre cleaning through the cascades. Largest dirt particles are led across the primary filter cascades directly to the sewer.
  3. Pre filtered water then flows over the secondary filter sieve (Mesh size 0.4 x 1 mm or 0.02 x .04 Inches). Due to the special mesh structure of the sieve, any dirt falls directly down onto the bottom of the shaft. In case of heavy rainfalls, the filter has more loss, as the water washes away the filtered dirt into the sewer.
  4. The cleaned water is being absorbed in the lower tank and directed through a tube DN 150 into the storage.
  5. Dirt goes to the sewer through the shaft.

Technical Data

Connection inlet: DN 200
Outlet into the tank: DN 150
Outlet into the sewer: DN 200

Height difference between inlet and outlet: 320 mm (12.6 Inches)

Material Filter corpus: Stainless steel 4016
Material Filter sieve: Stainless steel 1.4301
Mesh size: 0.4 x 1 mm (0.02 x .04 Inches)

Legs: Thread rods M10 with screw nut made of stainless steel, Length 250 mm (9.9 Inches)

Weight: 24.2 kg (53.2 lbs)

A 670 mm (26.4 Inches)
B 540 mm (21.3 Inches)
C 475 mm (18.7 Inches)
D 390 mm (15.4 Inches)
E 320 mm (12.6 Inches)
F 275 mm (10.8 Inches)
G 320 mm (12.6Inches)

Example 1

Installation of a filter in a pilot shaft.

Example 2

Installation of the filter in front of several concrete tanks which are situated in a row.

Optimal Installation

If the size of the roof or the diameters of the tubes should vary from the specifications / requirements, you can make an installation according to the DIN as demonstrated below.



Volume Filter VF-3

Description

Highly efficient two step cascade filtration, independent of flow rate. For larger roof areas where underground installation is desired utilizing a pre-cast concrete manhole or vault. Typically, 1200 mm (50-inch) diameter pre-cast concrete vaults are used.

Due to the steep inclination of the filter cartridge the debris are continuously carried away with each rain event. The outlet pipe is connected at the base of the pre-cast vault wall. The debris fall down to the bottom of the vault and are carried out downstream. The filtered water is conveyed into the storage tank.

Relative connection capacity for roof areas up to 11,750 ft². A bypass-installation is also available for larger roof areas.

Max. Flow Rate Sieve insert 4.5/sec = 16.2 m³ (21.18 ft³) filtered water per hour.

Inlet rainwater: 2 x 200 mm (8-inches)
Outlet into tank: 150 mm (6-inches)
Outlet into waste stream: 200 mm (8-inches)
Height difference between inlet and outlet 320 mm (12.6-inches).

Depending on the amount of debris loading, the filter only has to be inspected 1 – 2 times during the year. During inspection cleaning may be necessary.

How it works

  1. As water arrives the level builds up and overtops the filter lip, so ensuring it is distributed evenly across the whole width of the filter cascade.
  2. Pre cleaning through the cascades. Largest dirt particles are led across the primary filter cascades directly to the sewer.
  3. Pre filtered water then flows over the secondary filter sieve (Mesh size 0.4 x 1 mm or 0.02 x .04 Inches). Due to the special mesh structure of the sieve, any dirt falls directly down onto the bottom of the shaft. In case of heavy rainfalls, the filter has more loss, as the water washes away the filtered dirt into the sewer.
  4. The cleaned water is being absorbed in the lower tank and directed through a tube DN 150 into the storage.
  5. Dirt goes to the sewer through the shaft.
  6. The Volume Filter VF3 has only one fin unit. On the opposite a baffle is mounted.

Technical Data

Connection inlet: 2 x DN 200
Outlet into storage: DN 150
Outlet into sewer: DN 200

Height difference between inlet and outlet: 320 mm (12.6 Inches)

Material Filter corpus: Stainless steel 4016
Material Filter sieve: Stainless steel 1.4301
Mesh size: 0.4 x 1 mm (0.02 x .04 Inches)

Legs: Thread rods M10 with screw nut made of stainless steel, Length 250 mm (9.9 Inches)

Weight: 33.2 kg (73lbs)

A 670 mm (26.4 Inches)
B 540 mm (21.27) Inches
C 525 mm (20.68) Inches
D 980 mm (38.61) Inches
E 320 mm (12.6) Inches
F 275 mm (10.83) Inches
G 880 mm (34.67) Inches

Example 1

Installation of a filter in a pilot shaft.

Example 2

Installation of the filter in front of several concrete tanks which are situated in a row.

Optimal Installation & Advice

If the size of the roof or the diameters of the tubes should vary from specifications/requirements, you can modify the installation according to the correct sizing.

On demand the filter can be equipped with only one inlet. Please indicate in order. The hole then will be closed with a blind.

The Volume Filter is equipped with only one fin unit. It can be converted into a VF4 afterwards.



Volume Filter VF-4

Description

Highly efficient two step cascade filtration, independent of flow rate. For larger roof areas where underground installation is desired utilizing a pre-cast concrete manhole or vault. Typically, 1200 mm (50-inch) diameter pre-cast concrete vaults are used.

Due to the steep inclination of the filter cartridge the debris are continuously carried away with each rain event. The outlet pipe is connected at the base of the pre-cast vault wall. The debris fall down to the bottom of the vault and are carried out downstream. The filtered water is conveyed into the storage tank.

Relative connection capacity for roof areas up to 18,000 ft². A bypass-installation is also available for larger roof areas.

Max. Flow Rate Sieve insert 91/sec = 32.4 m³ (42.37 ft³) filtered water per hour.

Rainwater Inlet: 2 x 250 mm (9.8-inches)
Outlet into storage tank: 150 mm (6-inches)
Outlet into waste stream: 250 mm (9.8-inches)
Height difference between inlet and outlet 320 mm (12.6-inches).

Depending on the amount of debris loading, the filter only has to be inspected 1 – 2 times during the year. During inspection cleaning may be necessary.

How it works

  1. As water arrives the level builds up and overtops the filter lip, so ensuring it is distributed evenly across the whole width of the filter cascade.
  2. Pre cleaning through the cascades. Largest dirt particles are led across the primary filter cascades directly to the sewer.
  3. Pre filtered water then flows over the secondary filter sieve (Mesh size 0.4 x 1 mm or 0.02 x .04 Inches). Due to the special mesh structure of the sieve, any dirt falls directly down onto the bottom of the shaft. In case of heavy rainfalls, the filter has more loss, as the water washes away the filtered dirt into the sewer.
  4. The cleaned water is being absorbed in the lower tank and directed through a tube DN 150 into the storage.
  5. Dirt goes to the sewer through the basin.

Technical Data

Connection inlet: 2 x DN 250
Outlet into storage: DN 150
Outlet into sewer: DN 250

Height difference between inlet and outlet: 320 mm (12.6 Inches)

Material Filter corpus: Stainless steel 4016
Material Filter sieve: Stainless steel 1.4301
Mesh size: 0.4 x 1 mm (0.02 x .04 Inches)

Legs: Thread rods M10 with screw nut made of stainless steel, Length 250 mm (9.9 Inches)

Weight: 39.5 kg (86.9 lbs)

A 670 mm (26.4 Inches)
B 540 mm (21.27) Inches
C 525 mm (20.68) Inches
D 980 mm (38.61) Inches
E 320 mm (12.6) Inches
F 275 mm (10.83) Inches
G 880 mm (34.67) Inches

Example 1

Installation of a filter in a primary basin.

Example 2

Installation of the filter in front of several concrete tanks which are situated in a row

Optimal Installation & Advice

If the size of the roof or the diameter of the piping varies from the normal specifications/requirements, you can modify the installation.

On demand the filter can be equipped with only one inlet. Please indicate in order. The hole then will be closed with a blind.



Volume Filter VF-6

Description

Highly efficient two step cascade filtration, independent of flow rate. For larger roof areas where underground installation is desired utilizing a pre-cast concrete manhole or vault. Typically, 1200 mm (50-inch) diameter pre-cast concrete vaults are used.

Due to the steep inclination of the filter cartridge the debris are continuously carried away with each rain event. The outlet pipe is connected at the base of the pre-cast vault wall. The debris fall down to the bottom of the vault and are carried out downstream. The filtered water is conveyed into the storage tank.

Relative connection capacity for roof areas up to 32,000 ft². A bypass-installation is also available for larger roof areas.

Max. Flow Rate Sieve insert 91/sec = 32.4 m³ (42.37 ft³) filtered water per hour.

Rainwater Inlet: 2 x 250 mm (9.8-inches)
Outlet into tank: 150 mm (6-inches)
Outlet into waste stream: 250 mm (9.8-inches)
Height difference between inlet and outlet 320 mm (12.6-inches).

Depending on the amount of debris loading, the filter only has to be inspected 1 – 2 times during the year. During inspection cleaning may be necessary.

How it works

  1. As water arrives the level builds up and overtops the filter lip, so ensuring it is distributed evenly across the whole width of the filter cascade.
  2. Pre cleaning through the cascades. Largest dirt particles are led across the primary filter cascades directly to the sewer.
  3. Pre filtered water then flows over the secondary filter sieve (Mesh size 0.4 x 1 mm or 0.02 x .04 Inches). Due to the special mesh structure of the sieve, any dirt falls directly down onto the bottom of the shaft. In case of heavy rainfalls, the filter has more loss, as the water washes away the filtered dirt into the sewer.
  4. The cleaned water is being absorbed in the lower tank and directed through a tube DN 150 into the storage.
  5. Dirt goes to the sewer through the shaft.

Technical Data

Connection inlet: 2 x DN 250
Outlet into storage: DN 200
Outlet into sewer: DN 250

Height difference between inlet and outlet: 320 mm (12.6 Inches)

Material Filter corpus: Stainless steel 4016
Material Filter sieve: Stainless steel 1.4301
Mesh size: 0.4 x 1 mm (0.02 x .04 Inches)

Legs: Thread rods M10 with screw nut made of stainless steel, Length 250 mm (9.9 Inches)

Weight: 39.5 kg (86.9 lbs)

A 670 mm (26.4 Inches)
B 540 mm (21.27) Inches
C 525 mm (20.68) Inches
D 980 mm (38.61) Inches
E 320 mm (12.6) Inches
F 275 mm (10.83) Inches
G 880 mm (34.67) Inches

Example 1

Installation of a filter in a pilot pre-cast basin.

Example 2

Installation of the filter in front of several concrete tanks which are situated in a row.

Optimal Installation & Advice

If the size of the roof or the diameter of the conveyance pipe varies from the specifications/requirements, you can modify the installation.

On demand the filter can be equipped with only one inlet. Please indicate in order. The hole then will be closed with a blind.